Bearingless electrical motor

Слайд 2

Problems of use mechanical bearing Solution - contactless electromagnetic suspension

Problems of use mechanical bearing

Solution - contactless electromagnetic suspension

Слайд 3

- + Power amplifier Power amplifier Position sensors Reference signal Electromagnet

-

+

Power
amplifier

Power
amplifier

Position
sensors

Reference
signal

Electromagnet

Electromagnet

Principle of operation of active magnetic bearing (AMB)

External action

force conduce to rotor shift

Spring up position-indicating signal, which give to regulator

Power amplifier rule by electromagnet
Forces return rotor in central position

Слайд 4

Motor with AMB Bearingless electrical motor Versions of electrical machine whith contactless rotor suspension

Motor with AMB

Bearingless electrical motor

Versions of electrical machine whith contactless rotor

suspension
Слайд 5

х у Principle of operation of bearingless modul Drive control system

х

у

Principle of operation of bearingless modul

Drive control system give ac voltage

on drive winding,
appear torque, rotor rotate

External action force conduce to rotor shift,
position-indicating signal give to suspension control system

Suspension control system rule by electromagnet
Force return rotor in central position