- 2. E2 alarm Open the door ,check if there is water in the inner tub 1.Check if
- 3. The water level when appear E2 error 6 Water level 2 Water level 1
- 4. Condition 1:no water in the inner tub when alarm If there is no water in the
- 5. Condition 2:water level in inner tub ≤water level 1 If E2 water level is 1 or
- 6. condition3:inner tub water level between level 1 to level 2 If the inner tub water level
- 7. Pressure switch 1、3 point on-off test icon In the PCB position ,check pressure switch 1,3 point
- 8. Condition 4:inner tub water level ≥water level 2 If the water level ≥water level 2, according
- 9. Flowmeter on-off signal test icon The flowmeter on the PCB position on-off signal Flowmeter Switch off
- 11. Скачать презентацию
E2 alarm
Open the door ,check if there is water in the
E2 alarm
Open the door ,check if there is water in the
1.Check if the faucet is opened
2.If the water inlet valve is breakdown
3.If the PCB is breakdown
4.If appear syphon
≤ water level 1
Re-start the test after troubleshooting
Y
1.Check if the water pressure is too low
2.Check if water inlet valve breakdown
1.Check if the flowmeter and its related components are faulty
2.If the PCB is breakdown
OK,
Alarm release
N
N
Water level 1~water level 2
≥ water level 2
If pressure switch and other relate parts breakdown
E2 inlet water alarm repair flow chart
The water level when appear E2 error
6
Water level 2
Water level 1
The water level when appear E2 error
6
Water level 2
Water level 1
Condition 1:no water in the inner tub when alarm
If there is
Condition 1:no water in the inner tub when alarm
If there is
1. Check whether the water valve connected to the dishwasher is open, if the water valve is not open, open the water valve and restart.
2. If the water valve is open and the water pressure is normal, please check if the water inlet valve is faulty or blocked. If the water inlet valve is faulty or blocked, please clean or replace the water inlet valve and restart it.
3. Check the PCB and harness , if water valve circuit is faulty, restart after troubleshooting.
4. If the above steps are normal, please check if the drainage pipe hang in required height, drain pipe is immersed in the water (causing siphon): due to the drainage pipe is not high enough to hang or draining pipe mouth is immersed in the water, leading to siphon, The water in the inner tub is drained through the draining pipe, resulting in E2 alarm. Please follow the instructions to hang the draining pipe and ensure that the drain is not immersed in the water and restart.
Condition 2:water level in inner tub ≤water level 1
If E2 water
Condition 2:water level in inner tub ≤water level 1
If E2 water
1. First check if the water pressure is normal, whether the water pressure is too low, after the water pressure is normal ,restart.
2. If the faucet is open and the water pressure is normal, please check whether the inlet valve is blocked. If the inlet valve is blocked, please clean or replace the inlet valve and restart.
condition3:inner tub water level between level 1 to level 2
If the
condition3:inner tub water level between level 1 to level 2
If the
1.First check if the pressure switch 1, 3 is closed (need to detect the pressure switch 1 and 3 terminals and computer board CN4 3,4pin), if the pressure switch 1, 3 is not closed, please check in order:
A, after removed the pressure switch, test if the action point / reset point is normal. B, pressure switch, whether leakage air and inlet water.
C, gas chamber cover, whether the poor welding or bulk front air port.
If E2 failure caused by the above device failure, please replace the corresponding device.
2. If the pressure switches 1 and 3 are normally closed during the E2 alarm (measured at 3 and 4 pins on the CN4 terminal of the PCB), replace the PCB and restart it.
Pressure switch 1、3 point on-off test icon
In the PCB position
Pressure switch 1、3 point on-off test icon
In the PCB position
Press switch 1,3 closed
CN4 terminal3.4pin
pressure switch 1,3 point on-off test
Press switch 1,3 open
Condition 4:inner tub water level ≥water level 2
If the water level
Condition 4:inner tub water level ≥water level 2
If the water level
1.Check if the PCB flowmeter terminal loose, if plugged normally.
2. Check if the flowmeter breakdown, detection method: the multimeter transferred to the diode file, the pen were connected to the PCB CN5 1,3 pin, restart the dishwasher, when the dishwasher inlet water, detected whether the flow meter on-off signal,( When the water signal is normal, it is a continuous sound of drops and drops. When the signal is abnormal, it is always disconnected or closed) If the flowmeter signal is abnormal (always on or off), please replace the flowmeter (or respirator) and then restart it .
3. . If the above steps are normal, please change the PCB, and restart.
Flowmeter on-off signal test icon
The flowmeter on the PCB position on-off
Flowmeter on-off signal test icon
The flowmeter on the PCB position on-off
Flowmeter
Switch off all the time
Airbreak flowmeter
PCB CN5 terminal 1、3pin